If the Felder does not start, make sure that the local disconnect is enabled and the three-position rotary switch [located left of the local disconnect above the green button] is turned to the clockwise position [toward the wall].  If the rotary switch is turned counterclockwise [toward the room], the Felder will be in a cleaning mode and occasionally blow air backward to try to purge/clean the filters.

Image Removed

The biggest problem with the dust collector is it is not being emptied enough.  Please check the dust collection cart if you are not sure when the last time it was emptied.  Always stop and empty the machine if the yellow warning light is illuminated (item #2).  If the unit gets too full, the sawdust will back up and start clogging the filters – greatly affecting the collection’s performance.

...

** Getting the cart back into place is the biggest pain of the sequence. If you look in the hole where the cart goes, you can see the two rails the bar rides along - make sure they are not covered in sawdust. Sometimes “resetting” the cart (lowering and raising the bar) a couple of times is necessary to get a decent seal between the cart and the machine.

Video:

Widget Connector
urlhttps://www.youtube.com/watch?v=c_f_oYsdhOg

...

View file
nameFelder_RL250_Manual.pdf
height250


Manufacturer's Website: https://www.felder-group.com/en-gb/products/dust-extractors-extraction-units-c1963/clean-air-dust-extractor-high-performance-line-p144347


Restricted processes:


Safe Operation:

...